3D model
DRAFT MODEL, NOT CERTIFIED GEOMETRY
Parts select to focus, Esc to reset
DRAFT MODEL, NOT CERTIFIED GEOMETRY
Demag
DC-Com 10-2000
Checked
3D
- Capacity
- 2000 kg
- Speed
- max 4 m/min
- Rating
- not sourced
- Weight
- 65 kg max. at 5 m hook path (63 kg at 4 m, 73 kg at 8 m)
Checked against a maker document.
Specifications
Lift
- Lifting speed
- 4.0 / 1.0 m/min at 50 Hz (4.8 / 1.2 at 60 Hz); the p.13 cell spans the 630-2000 kg rows, 2/1 included
- Secondary speed
- 1.0 m/minSource document
- Min speed (VFD)
- —
- Speed type
- Two speed (main and creep lifting, ratio F4)Source document
- Lift height
- —
- Hook path
- —
Chain
- Chain (Ø × pitch)
- 7.4 x 21.2 mmSource document
- Chain grade
- DAT (Demag RDC/TDK standard chain)Source document
- Chain fall
- 2 falls
Duty
- Duty class / cycle
- 40/20 % CDF; FEM 2m / ISO M5 at 2000 kg (DIN EN 14492)
- %ED, starts per hour
- 60 % (40 % / 20 %) CDF, 360 (120 / 240) switching operations per hourSource document
Electrical
- Motor power
- ZNK 100 B 8/2 (two-speed)
- Supply
- 400V 3Ph
- Current draw
- IN 3.00-3.40 A (8 poles) / 5.50-6.20 A (2 poles); start-up IA/IN max 1.85 / 4.15Source document
- Control voltage
- 24 V contactor controlSource document
- Brake
- Separate DC brake beneath the electric equipment cover, double encapsulatedSource document
Body
- Housing material
- Aluminium housing parts, UV-resistant powder coatingSource document
- Dimensions
578 x 349 x 187 mm (l x b x d; b 409 with chain collector H8); C 564 / 597 mm with the short / long…
578 x 349 x 187 mm (l x b x d; b 409 with chain collector H8); C 564 / 597 mm with the short / long suspension bracket (p.19); C1 582 / 632 (short bracket, collector H4/H5 / H8); +60 mm with the external cut-off spring bottom block- Protection (IP)
- IP54
- Noise
- 68 dB(A)
- Operating temperature
- -20 °C to +45 °C without reduction of the duty factorSource document
Safety
- Overload protection
- Slipping clutch with automatic cut-out by speed monitoring (no continuous slipping)Source document
- Upper limit switch
- Operating limit switch for the upper hook position, standardSource document
- Lower limit switch
- Operating limit switch for the lower hook position, standardSource document
- Emergency stop
- Emergency stop (safety function, PL at least c)Source document