1 / 28

3D model

Rendered view of the Demag DC-Com 2-250 3D model

DRAFT MODEL, NOT CERTIFIED GEOMETRY

Parts select to focus, Esc to reset

DRAFT MODEL, NOT CERTIFIED GEOMETRY

Demag

DC-Com 2-250

Checked 3D
Capacity
250 kg
Speed
6 m/min
Rating
not sourced
Weight
22 kg max. at 5 m hook path (21 kg at 4 m, 24 kg at 8 m)
DC-Com sizes

Checked against a maker document.

Maker page Ask

Specifications

Lift

Lifting speed
6.0 / 1.5 m/min at 50 Hz (7.2 / 1.8 at 60 Hz)
Secondary speed
1.5 m/minSource document
Min speed (VFD)
—
Speed type
Two speed (main and creep lifting, ratio F4)Source document
Lift height
—
Hook path
—

Chain

Chain (Ø × pitch)
4.2 x 12.2 mmSource document
Chain grade
DAT (Demag RDC/TDK standard chain)Source document
Chain fall
1 fall

Duty

Duty class / cycle
40/20 % CDF; FEM 2m / ISO M5 at 250 kg (DIN EN 14492)
%ED, starts per hour
60 % (40 % / 20 %) CDF, 360 (120 / 240) switching operations per hourSource document

Electrical

Motor power
ZNK 71 B 8/2 (two-speed)
Supply
400V 3Ph, 230V 1Ph
Current draw
IN 1.00-1.20 A (8 poles) / 1.40-1.60 A (2 poles); start-up IA/IN max 1.45 / 2.75Source document
Control voltage
24 V contactor controlSource document
Brake
Separate DC brake beneath the electric equipment cover, double encapsulatedSource document

Body

Housing material
Aluminium housing parts, UV-resistant powder coatingSource document
Dimensions
422 x 268 x 124 mm (l x b x d; b for chain collector H4/H5); C 326 / 364 mm with the short / long suspension…422 x 268 x 124 mm (l x b x d; b for chain collector H4/H5); C 326 / 364 mm with the short / long suspension bracket; C1 335 / 365 (short bracket, collector H4/H5 / H8)
Protection (IP)
IP54
Noise
62 dB(A)
Operating temperature
-20 °C to +45 °C without reduction of the duty factorSource document

Safety

Overload protection
Slipping clutch with automatic cut-out by speed monitoring (no continuous slipping)Source document
Upper limit switch
Optional (lifting/lowering limit switch, DC-Com 1/1)Source document
Lower limit switch
Optional (lifting/lowering limit switch, DC-Com 1/1)Source document
Emergency stop
Emergency stop (safety function, PL at least c)Source document

Documents

3

Ask about this hoist

Answers use verified records only