8 / 22

3D model

Rendered view of the Demag DC-Com 10-2000 3D model

DRAFT MODEL, NOT CERTIFIED GEOMETRY

Parts select to focus, Esc to reset

DRAFT MODEL, NOT CERTIFIED GEOMETRY

Demag

DC-Com 10-2000

Checked 3D
Capacity
2000 kg
Speed
max 4 m/min
Rating
not sourced
Weight
65 kg max. at 5 m hook path (63 kg at 4 m, 73 kg at 8 m)
DC-Com sizes

Checked against a maker document.

Maker page Ask

Specifications

Lift

Lifting speed
4.0 / 1.0 m/min at 50 Hz (4.8 / 1.2 at 60 Hz); the p.13 cell spans the 630-2000 kg rows, 2/1 included
Secondary speed
1.0 m/minSource document
Min speed (VFD)
—
Speed type
Two speed (main and creep lifting, ratio F4)Source document
Lift height
—
Hook path
—

Chain

Chain (Ø × pitch)
7.4 x 21.2 mmSource document
Chain grade
DAT (Demag RDC/TDK standard chain)Source document
Chain fall
2 falls

Duty

Duty class / cycle
40/20 % CDF; FEM 2m / ISO M5 at 2000 kg (DIN EN 14492)
%ED, starts per hour
60 % (40 % / 20 %) CDF, 360 (120 / 240) switching operations per hourSource document

Electrical

Motor power
ZNK 100 B 8/2 (two-speed)
Supply
400V 3Ph
Current draw
IN 3.00-3.40 A (8 poles) / 5.50-6.20 A (2 poles); start-up IA/IN max 1.85 / 4.15Source document
Control voltage
24 V contactor controlSource document
Brake
Separate DC brake beneath the electric equipment cover, double encapsulatedSource document

Body

Housing material
Aluminium housing parts, UV-resistant powder coatingSource document
Dimensions
578 x 349 x 187 mm (l x b x d; b 409 with chain collector H8); C 564 / 597 mm with the short / long…578 x 349 x 187 mm (l x b x d; b 409 with chain collector H8); C 564 / 597 mm with the short / long suspension bracket (p.19); C1 582 / 632 (short bracket, collector H4/H5 / H8); +60 mm with the external cut-off spring bottom block
Protection (IP)
IP54
Noise
68 dB(A)
Operating temperature
-20 °C to +45 °C without reduction of the duty factorSource document

Safety

Overload protection
Slipping clutch with automatic cut-out by speed monitoring (no continuous slipping)Source document
Upper limit switch
Operating limit switch for the upper hook position, standardSource document
Lower limit switch
Operating limit switch for the lower hook position, standardSource document
Emergency stop
Emergency stop (safety function, PL at least c)Source document

Documents

3

Ask about this hoist

Answers use verified records only