68 / 331

3D model

Rendered view of the Demag DC-Pro 1-125 3D model

DRAFT MODEL, NOT CERTIFIED GEOMETRY

Parts select to focus, Esc to reset

DRAFT MODEL, NOT CERTIFIED GEOMETRY

Demag

DC-Pro 1-125

Checked 3D
Capacity
125 kg
Speed
8 m/min
Rating
not sourced
Weight
22 kg max. at 5 m hook path, 24 kg at 8 m

Checked against a maker document.

Maker page Ask

Specifications

Lift

Lifting speed
8.0 / 2.0 m/min at 50 Hz (9.6 / 2.4 at 60 Hz)
Secondary speed
2.0 m/minSource document
Min speed (VFD)
—
Speed type
Two speed (main and fine lifting, ratio F4)Source document
Lift height
5 and 8 mSource document
Hook path
—

Chain

Chain (Ø × pitch)
4.2 x 12.2 mm
Chain grade
Demag special chain, high-strength, ageing-resistant, high surface hardness, galvanisedSource document
Chain fall
1 fall

Duty

Duty class / cycle
FEM 4m / ISO M7 (DIN EN 14492)
%ED, starts per hour
60 % ED, 360 s/hSource document

Electrical

Motor power
ZNK 71 A 8/2 (pole-changing, 2 speeds)
Supply
—
Current draw
—
Control voltage
24 V contactor controlSource document
Brake
Brake directly on the load line, double encapsulated (doppelgekapselt)Source document

Body

Housing material
Aluminium die-castSource document
Dimensions
body 422 x 268 x 124 mm (L x W x H; L = l, the length along the motor axis. W = b, the width across the front…body 422 x 268 x 124 mm (L x W x H; L = l, the length along the motor axis. W = b, the width across the front view. H = d, the motor-housing height. C and C1 are headroom to the hook and are not H. Row DC-Pro 1, shared with DC-Pro 2, motor ZNK 71 B 8/2.); C_short 326, C_long 364, C1_H5_short 335, C1_H8_short 365, C1_H5_long 373, C1_H8_long 403, b 268, l 422, b3 183, d 124 mm; (dimension_drawing_dc-pro_p32-33.pdf p.1)
Protection (IP)
IP 55 (hoist motor, chain hoist, travel drive); IP 65 (control pendant)Source document
Noise
—
Operating temperature
—

Safety

Overload protection
Slipping clutch in the load line behind the brake, with speed monitoringSource document
Upper limit switch
Operating limit switch (top), standardSource document
Lower limit switch
Operating limit switch (bottom), standardSource document
Emergency stop
Emergency stop (safety function, PL at least c)Source document

Documents

4

Ask about this hoist