3D model
DRAFT MODEL, NOT CERTIFIED GEOMETRY
Parts select to focus, Esc to reset
DRAFT MODEL, NOT CERTIFIED GEOMETRY
Demag
DC-Pro 1-125
Checked
3D
- Capacity
- 125 kg
- Speed
- 8 m/min
- Rating
- not sourced
- Weight
- 22 kg max. at 5 m hook path, 24 kg at 8 m
Checked against a maker document.
Specifications
Lift
- Lifting speed
- 8.0 / 2.0 m/min at 50 Hz (9.6 / 2.4 at 60 Hz)
- Secondary speed
- 2.0 m/minSource document
- Min speed (VFD)
- —
- Speed type
- Two speed (main and fine lifting, ratio F4)Source document
- Lift height
- 5 and 8 mSource document
- Hook path
- —
Chain
- Chain (Ø × pitch)
- 4.2 x 12.2 mm
- Chain grade
- Demag special chain, high-strength, ageing-resistant, high surface hardness, galvanisedSource document
- Chain fall
- 1 fall
Duty
- Duty class / cycle
- FEM 4m / ISO M7 (DIN EN 14492)
- %ED, starts per hour
- 60 % ED, 360 s/hSource document
Electrical
- Motor power
- ZNK 71 A 8/2 (pole-changing, 2 speeds)
- Supply
- —
- Current draw
- —
- Control voltage
- 24 V contactor controlSource document
- Brake
- Brake directly on the load line, double encapsulated (doppelgekapselt)Source document
Body
- Housing material
- Aluminium die-castSource document
- Dimensions
body 422 x 268 x 124 mm (L x W x H; L = l, the length along the motor axis. W = b, the width across the front…
body 422 x 268 x 124 mm (L x W x H; L = l, the length along the motor axis. W = b, the width across the front view. H = d, the motor-housing height. C and C1 are headroom to the hook and are not H. Row DC-Pro 1, shared with DC-Pro 2, motor ZNK 71 B 8/2.); C_short 326, C_long 364, C1_H5_short 335, C1_H8_short 365, C1_H5_long 373, C1_H8_long 403, b 268, l 422, b3 183, d 124 mm; (dimension_drawing_dc-pro_p32-33.pdf p.1)- Protection (IP)
- IP 55 (hoist motor, chain hoist, travel drive); IP 65 (control pendant)Source document
- Noise
- —
- Operating temperature
- —
Safety
- Overload protection
- Slipping clutch in the load line behind the brake, with speed monitoringSource document
- Upper limit switch
- Operating limit switch (top), standardSource document
- Lower limit switch
- Operating limit switch (bottom), standardSource document
- Emergency stop
- Emergency stop (safety function, PL at least c)Source document