57 / 379

3D model

Rendered view of the Demag DC-Pro 5-500 3D model

DRAFT MODEL, NOT CERTIFIED GEOMETRY

Parts select to focus, Esc to reset

DRAFT MODEL, NOT CERTIFIED GEOMETRY

Demag

DC-Pro 5-500

Checked 3D
Capacity
500 kg
Speed
8 m/min
Rating
not sourced
Weight
28 kg max. at 5 m hook path, 30 kg at 8 m

Checked against a maker document.

Maker page Ask

Specifications

Lift

Lifting speed
8.0 / 2.0 m/min at 50 Hz (9.6 / 2.4 at 60 Hz)
Secondary speed
2.0 m/minSource document
Min speed (VFD)
—
Speed type
Two speed (main and fine lifting, ratio F4)Source document
Lift height
—
Hook path
—

Chain

Chain (Ø × pitch)
5.3 x 15.2 mm
Chain grade
Demag special chain, high-strength, ageing-resistant, high surface hardness, galvanisedSource document
Chain fall
1 fall

Duty

Duty class / cycle
FEM 2m+ / ISO M5+ (DIN EN 14492; 2m+ = 1900 h at full load)
%ED, starts per hour
60 % ED, 360 s/hSource document

Electrical

Motor power
ZNK 80 B 8/2 (pole-changing, 2 speeds)
Supply
—
Current draw
—
Control voltage
24 V contactor controlSource document
Brake
Brake directly on the load line, double encapsulated (doppelgekapselt)Source document

Body

Housing material
Aluminium die-castSource document
Dimensions
body 468 x 280 x 151 mm (L x W x H; L = l, the length along the motor axis. W = b, the width across the front…body 468 x 280 x 151 mm (L x W x H; L = l, the length along the motor axis. W = b, the width across the front view. H = d, the motor-housing height. C and C1 are headroom to the hook and are not H. Row DC-Pro 5, motor ZNK 80 B 8/2.); C_short 378, C_long 316, C1_H5_short 395, C1_H8_short 425, C1_H5_long 435, C1_H8_long 465, b 280, l 468, b3 195, d 151 mm; (dimension_drawing_dc-pro_p32-33.pdf p.1)
Protection (IP)
IP 55 (hoist motor, chain hoist, travel drive); IP 65 (control pendant)Source document
Noise
—
Operating temperature
—

Safety

Overload protection
Slipping clutch in the load line behind the brake, with speed monitoringSource document
Upper limit switch
Operating limit switch (top), standardSource document
Lower limit switch
Operating limit switch (bottom), standardSource document
Emergency stop
Emergency stop (safety function, PL at least c)Source document

Documents

4

Ask about this hoist

Answers use verified records only