3D model
DRAFT MODEL, NOT CERTIFIED GEOMETRY
Parts select to focus, Esc to reset
DRAFT MODEL, NOT CERTIFIED GEOMETRY
Demag
DC-Pro 10-2000
Checked
3D
- Capacity
- 2000 kg
- Speed
- 6 m/min
- Rating
- not sourced
- Weight
- 65 kg max. at 5 m hook path, 73 kg at 8 m
Checked against a maker document.
Specifications
Lift
- Lifting speed
- 6.0 / 1.5 m/min at 50 Hz (7.2 / 1.8 at 60 Hz)
- Secondary speed
- 1.5 m/minSource document
- Min speed (VFD)
- —
- Speed type
- Two speed (main and fine lifting, ratio F4)Source document
- Lift height
- 5 and 8 mSource document
- Hook path
- —
Chain
- Chain (Ø × pitch)
- 7.4 x 21.2 mm, 2 falls
- Chain grade
- Demag special chain, high-strength, ageing-resistant, high surface hardness, galvanisedSource document
- Chain fall
- 2 falls
Duty
- Duty class / cycle
- FEM 2m+ / ISO M5+ (DIN EN 14492; 2m+ = 1900 h at full load)
- %ED, starts per hour
- 60 % ED, 360 s/hSource document
Electrical
- Motor power
- ZNK 100 B 8/2 (pole-changing, 2 speeds)
- Supply
- —
- Current draw
- —
- Control voltage
- 24 V contactor controlSource document
- Brake
- Brake directly on the load line, double encapsulated (doppelgekapselt)Source document
Body
- Housing material
- Aluminium die-castSource document
- Dimensions
body 578 x 349 x 187 mm (L x W x H; L = l. W = b for chain collector H5 (349). b for chain collector H8 is…
body 578 x 349 x 187 mm (L x W x H; L = l. W = b for chain collector H5 (349). b for chain collector H8 is 409 and is not W. H = d, the motor-housing height. C and C1 are headroom to the hook and are not H.); C_short 541, C_long 574, C1_H5_short 582, C1_H8_short 582, C1_H5_long 615, C1_H8_long 615, b_H5 349, b_H8 409, b3_H5 227, b3_H8 330, l 578, d 187 mm; (data_sheet_dc-pro_masstabellen.pdf p.1)- Protection (IP)
- IP 55 (hoist motor, chain hoist, travel drive); IP 65 (control pendant)Source document
- Noise
- —
- Operating temperature
- —
Safety
- Overload protection
- Slipping clutch in the load line behind the brake, with speed monitoringSource document
- Upper limit switch
- Operating limit switch (top), standardSource document
- Lower limit switch
- Operating limit switch (bottom), standardSource document
- Emergency stop
- Emergency stop (safety function, PL at least c)Source document